Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
INSULATING CASTABLES
Particulars MR Insulyte 7 MR Insulyte 9 MR Insulyte 11 MR Insulyte 13 MR Insulyte 15
PHYSICAL PROPERTIES
Recommended Services
Temp. OC 1100 1100 1350 1350 1350
Dry Density (kg/m3) 750-850 900-1000 1140-1250 1300-1450 1500-1600
Thermal Conductivity (K Cal/m/hr/0C) 0.14 0.28 0.31 0.33 0.44
CCS (kg/cm2) 110OC 12-14 15-20 35-45 50-60 90-100
800OC 4-6 6-8 25-30 30-40 60-70
1100OC 6-8 10-14 25-30 30-40 60-70
1300OC - - 40-45 50-70 70-90
PLC (%) 100OC - - - - -
500OC - ±0.2 - - -
800OC ±1.0 ±0.6 - - -
1100OC ±1.6 ±1.0 ±0.2 ±0.2 ±0.2
1300OC - - ±1.0 ±0.6 ±0.6
CHEMICAL ANAYSIS
Fe2O33 (%) Max. 8.5 6 3.5 3.5 3.2
NOTE :
CCS and PLC values are on 4 x 4 x 16 cm prisms. Thermal Conductivity prefired hot face 500OC.
Data represents typical average properties & do not constitute a specification.